  • ENGLISH
  • |
  • 中文版
Load CellHome > Load Cell > Force measure load cell

FA101

Features&Parameters

●Low height, small deformation and small size

●Stainless steel material

●High temperature performance can be customized for injection moulding, backlog and other manufacturing processes.

●It is suitable for automobile pressing, automatic assembly, 3C product testing, new energy product assembly, medical inspection, robotics, die assembly and other industrial testing, measurement and control systems.

●High frequency of dynamic response

Data sheet download Inquiry
Description

Mounting Dimension

Load Direction

Wiring Code


Specifications

Technique

Capacity

20,50,100,200,    300N,500N

Rated output

1.0±20%mV/V

Zero balance

±0.05mV/V

Non-linearity

0.5%F.S.

Hysteresis

0.5%F.S.

Repeatability

0.5%F.S.

Input impedance

600~800Ω

Output impedance

600~800Ω

Insulation

≥5000MΩ/100VDC

Recommended excitation

5~12V

Maximum excitation Voltage

15V

Compensated temp range

-10~60℃

Operation temp range

-20~80℃

Temp.effect on output

0.05%F.S./10℃

Temp.effect on zero

0.05%F.S./10℃

Safe overload

150%F.S.

Ultimate overload

300%F.S.

Cable size

φ2×3000mm

TEDS optional

Inquiry

Previous : FA102
Next : No record